Backgroundimage

Industry - environmental simulation

The test systems in our environmental simulation laboratory are designed for normative and customer-specific test requirements. The know-how of our test engineers is based on years of professional experience in handling your products from a wide variety of areas. This is the basis for the implementation and testing of your current and future product requirements.


Climatic tests in the range of - 50 ° C up to 180 ° C, with or without humidity option, with a test room volume of 0.5 m³ up to 24 m³ and vibration tests up to a total weight of max. 2t, e.g. Control cabinets, air conditioning units or printers are marginal values of our possibilities.

Accreditation/certification

Accreditations: DIN EN ISO/IEC 17025:2018
Certifications: DIN EN ISO 9001:2015 and DIN EN ISO 14001:2015

Typical Standards for the applications listed above

Mechanical tests

  • DIN EN 60068-2-6 (oscillation, sinusoidal)
  • DIN EN 60068-2-27 (shock)
  • DIN EN 60068-2-64 (oscillation, noise-like)
  • DIN EN 60068-2-53 (combined climatic (temperature / humidity) and
    dynamic (vibration / shock) tests
     

Temperature tests

  • DIN EN 60068-2-1 / -2 (cold / dry heat)
  • DIN EN 60068-2-14 (temperature change)
     

Climatic tests

  • DIN EN 60068-2-30 (damp heat, cyclical)
  • DIN EN 60068-2-38 (temperature / humidity, cyclical)
  • DIN EN 60068-2-74 (damp heat, constant)
     

Corrosion tests

  • DIN EN 60068-2-11 (salt fog)
  • DIN EN 60068-2-52 (salt spray, cyclical)
  • DIN EN 60068-2-60 (mixed / harmful gas)
     

Protection classes (IP code)

  • DIN EN 60529 (degrees of protection through housing)
  • ISO 20653 (road vehicles - degrees of protection)
     
Environmental simulationd laboratory equipment

Electrodynamic vibration test systems from 20 kN to 300 kN, with temperature or climate overlay

  • Vibration test systems with and without slide table
  • Various clamping devices: Headexpander, cube, H-piece etc.
  • Additional storage to enlarge the clamping area for large parts
  • Max. Temperature range: - 70 ° C to + 180 ° C
  • Humidity range: between 10% and 95% rel. F.
     

Construction (bench design)

  • Fixture construction / fixture adjustments
  • 2D construction / 3D design
  • CAD simulation (optional)
     

Temperature and climatic chamber from 0.3 m³ to 25 m³

  • Max. Temperature range: - 70 ° C to + 180 ° C
  • possible rel. Humidity 20% to 98%
  • Options: Sun simulation, corrosive gas, condensation, special tests according to various manufacturer specifications (on request)
     

Temperature shock chambers

  • Air-air, over 120 l / 500 l to 7 m³ (air humidity on request)
  • Temperature shock with splash water (optional: with / without Arizona dust)
  • Temperature shock diving
     

Corrosion change chambers 0.5 m³ to 11 m³

  • Option: special tests according to various manufacturer specifications (e.g. Nissan, Ford, VW Group, VDA, etc.)
     

IP protection class test (ISO 20653, optionally DIN EN 60529)

  • Foreign body and contact protection: IP 1X to IP 4X (1st code number)
  • Dust test: IP 5KX to IP 6KX (1st code number)
  • Water protection: IP X1 to IP X8 and IP X4K, IPx6K and X9K (2nd code number)
  • Special tests on request
     

Acoustics

  • Sound power measurement or Squeak & Rattle in a half-space of quality class 1
     

Surface tests

  • Testing of decorative and functional surfaces
  • Determination of hardness, abrasion resistance, color, gloss and adhesion
  • Determination of the burning behavior of materials used in motor vehicle interiors
  • Chemical tests: resistance to reagents
     

Electrical tests

  • according to customer specifications and / or technical standards
     

Monitoring systems for test item monitoring and control

  • Measurement data acquisition and evaluation of customer-specific specifications
  • multi-channel imprint of specific current profiles
  • automat. Test stands for the actuation of mechanical components
  • and much more

Monitoring media equipment
  • Reproducible constructions on pre-assembled vibration equipment
  • Standardized measuring procedure for recording analog measured values
  • Various bus monitoring systems such as LAN, INTERBUS, DeviceNet™, Ethernet, and PROFIBUS